50 Hz
Images are Caterpillar product images; the actual unit varies with enclosure, tank and options.
Cat GC series · diesel generator
Cat DE660 GC 660 kVA
High-output standby power for hotels, hospitals, shopping centres, factories and large construction sites; suitable for synchronised systems. Powered by the Cat® C15 engine, 380 – 415 V / 50 Hz.
660 kVAStandby power
528 kW0.8 pf
C15Engine
3,794 kgDry weight (max.)
- Installation and commissioning
- Scheduled maintenance · 24/7 breakdown service
- Genuine Cat spare parts
- ATS / synchronising panel integration
Generator set
| Standby power | 660 kVA / 528 kW* |
|---|---|
| Prime power | 600 kVA / 480 kW* |
| Frequency | 50 Hz |
| Voltage | 380 – 415 V |
| Speed | 1500 rpm |
| Phase | 3-phase |
| Power factor | 0.8 pf |
| Emissions / fuel strategy | Low fuel consumption (low BSFC) |
| Control panel | GCCP 1.1 |
| Alternator | A-Frame standard alternator |
| Ambient temperature | Full power up to 55 °C |
Engine
| Engine model | Cat® C15 |
|---|---|
| Configuration | In-line 6-cylinder, 4-stroke diesel |
| Bore x stroke | 137 x 171 mm |
| Displacement | 15.2 L |
| Compression ratio | 16.1:1 |
| Aspiration | Turbocharged, air-to-air aftercooled |
| Fuel system | Electronic unit injector (EUI) |
| Governor | Electronic – ADEM™ A4 |
| Fuel | Diesel |
Dimensions & weight
| Length (max.) | 3,328 mm |
|---|---|
| Width (max.) | 1,540 mm |
| Height (max.) | 2,187 mm |
| Dry weight | 3,794 kg |
Dimensions are maximum values and vary with enclosure and tank options.
- GCCP 1.1 generator control panel
- Cat electronic governor (ADEM™ A4)
- A-Frame standard alternator
- Single-wall 8-hour fuel tank
- Skid-mounted radiator with guarded fan
- 3-pole circuit breaker
- 24 V battery, rack and cables
- Dry-type air cleaner
- Fuel filters with water separator
- Vibration isolators
- Caterpillar yellow paint
- Cat® Product Link™ remote monitoring
- Cat GC sound-attenuated enclosure
- Industrial / critical grade silencer
- 4-pole circuit breaker
- Battery charger
- Alternator anti-condensation heater
- PMG (permanent magnet) excitation
- Emergency stop button
- Double-wall fuel tank
- Fuel tank with spill containment
- CE / EAC / GCC certification
- ATS transfer panel (JUTEK)
- Synchronising panel (JUTEK)
* kW values are calculated at 0.8 power factor. Data is based on Caterpillar publications, is for information only and subject to change. Final values are confirmed with the quotation. Cat® and Caterpillar® are registered trademarks of Caterpillar Inc.